pulse oximeter units line powered

0 out of 5
Category: I.C.U. Equipment

Description

Descriptions

GMDN name and Code Pulse oximeter CT 1446
“Pulse Oxymeter, line Powered:A mains electricity (AC-powered) photoelectric device intended for the continuous transcutaneous measurement and display of haemoglobin oxygen saturation (SpO2) The signals, typically produced by light-emitting diodes (LEDs) and a receiving detector in a probe, or directly built-in, are used to make the measurements using the principle of spectrophotometry The oximeter displays the SpO2 values and may calculate / display other parameters, e g , pulse rate, electrocardiogram (ECG) The device is typically used at the bedside “ yes
SpO2 measurement range at least 40-70 and 70 to 99 %, minimum gradation 1% yes
Power consumption 220 Watt
power input and frequency 220 to 240V, 50 Hz
Accuracy of pulse rate better than ± 5 bpm yes
Audiovisual alarms required: high and low SpO2 and pulse rate (operator variable settings), sensor disconnected,sensor failure, low battery yes
Display type TFT Screen
Heat Dissipiation: Should maitain nominal Temp and the heat should be disbursed through a exhaust cooling fan yes
Mobility, portability Protective splashproof case for clean storage and safe transport
Operating condition:Capable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances yes
weight (gram) 2951
Others: List of important spare parts and accessories with their part number, Certificate of Calibration and Inspection to be provided YES
STANDARDS AND SAFETY:Should be FDA / CE approved product ISO 80601-2-61-2011: Medical Electrical equipment- part 2-61: Particular requirements for the basic safety snd essential performance of pulse oxymeter Electrical safety conforms to standards for electrical safety IEC-60601-1, EMC safety confirms to IEC 60601-1-2 standard requirement; Manufacturer / supplier should have ISO 13485 certificate for quality standard Electrical safety conforms to standards for electrical safety IEC-60601-1 Shall meet IEC-60601-1-2 (General requirements for safety – electromagnetic compatibility) and IEC 60601-2-25 (essential performance of electrocardiographs) yes
Accuracy of SpO2 better than ± 1% for range 40-70 and better than ± 3% for range 70-99 yes
Pulse rate range at least 30 to 240 bpm, minimum gradation 1 bpm yes
Power cable length (meter) 3
Signal strength or quality to be visually displayed yes
Memory Minimum 24 hrs trend memory for SpO2 & PR
Noise Level (dB) 2
User’s interface Easily accessible touch button to operate the machine
Inbuilt Software and/or standard of communication yes
Display must allow easy viewing in all ambient light levels yes
Electrical protection provided by fuses in both live and neutral supply lines yes

Warranty

Warranty 3 years warranty & one year with min. 3 free servicing.