COMPUTED RADIOGRAPHY SYSTEM

0 out of 5

Description

TYPE

Type of computed radiography (CR) SystemMulti Loading Computed Radiography System (MLCRS)

COMPATIBILITY

CR System compatible with standard X-ray Machine consisting of Digitizer Patient Identification System, Preview And Processing Server with WorkstationYes
C R System to be supplied with compatible Cassettes & Imaging Plates for RecordingYes

ACCESSORIES FOR MULTI LOADING CR SYSTEM

Imaging plate and Cassette (dimensions in inch x inch) set offered with Multi loading computed radiography system14×17, 14×14, 10×12, 8x10sizes-Img.Plate & Castt.-9 units each, 8×10,10x12sizes-Img.Plate& Mammo.Castt-4 units each

ACCESSORIES FOR SINGLEI LOADING CR SYSTEM

Imaging plate and Cassette (dimensions in inch x inch) set offered with Single loading computed radiography system14×17, 10×12, sizes-Img.Plate & Castt.- 9 units each

IMAGE READER

For the largest Imaging plate/Cassette size, the Images Reading (CR Reader) / Digitizer is able to process >=75 Imaging Plates/hour (for offered multi loading computed radiography system)
CR Reader/Digitizer should have Pre-set Anatomical Processing facility, acquisition and Image transfer at a resolution 12 Bits/pixelYes
CR Reader/Digitizer should have Status Display facility preferably on a LCD Display Indicating Error Status etcYes
CR Reader/Digitizer should have Scanning Resolution of (5-10 Pixels/mm Or More)Yes
CR Reader/Digitizer should have ability to route Images To Multiple Destinations Like Work Stations, Dry Camera etcYes
If multi loading computerised system, CR Reader/Digitizer to be supplied along with an Input and Output Cassette Buffer/stacker for >=4 Cassettes eachYes
CR Reader/Digitizer should have a scanning resolution>= 20 Pixel/mm for General Cassette Reading and for Mammography And Extremities, multi loading CR system

CENTRALISED PATIENT STUDY MANAGEMENT (CPSM) UNIT

Processing Server And Workstation With 21 Inch LCD Monitor for Centralized Patient Study Management (CPSM) unitYes
CPSM unit should have features: (i) Work Station must be able to receive CR Images From Digitizer (ii) DICOM Ready For Sent, Receive And Print Facility ProtocolYes
CPSM unit should have features: (iii) Possible To Multi-formatting The Images On Film For Printing (iv) 21 Inch LCD Monitor For Patient Study Management (v) Possible To Write Images On A CD/DVDYes
CPSM unit should have features: (vi) Ready To Accept Images From Work List And Patient Data And Images Another RIS/HIS (DICOM PROTOCOL) (vii) Black Border FacilityYes
CPSM unit should have features: (viii) Software For Printing And To Create Various Film Layouts And Multiple Formats On Single Film For Optimum Utilization Of Film And PresentabilityYes
CPSM unit should have The Capability To Customise User Defined No of Formats And Layouts On The Single FilmYes
CPSM unit should have capability of Printing the Zoomed Image along with The Overview of the Main Image on same filmYes
CPSM unit should have capability of Printing Multiple Patient Images on one Film And Multiple Images of same Patient on One FilmYes
CPSM unit should have features: Image Gray Scale Reversal, Image Flipping And Rotating, Image ZoomingYes
CPSM unit should have features: Edge Enhancement, Latitude Reduction, Image Noise Reduction, Gray Scale Saturation FeedbackYes
CPSM unit should have provision For Adding MarkersYes
Patient Identification/ Preview (i) Separate Or Inbuilt Patient Identification System (ii) Cassette Identification And Demographics Should Be Standard (iii) It Should Be Possible To Identify The Multi X-ray Units SeparatelyYes

DRY IMAGER

Dry Imager (For Film Printing) to be supplied with offered Single /Multi loading CR System, should be with a Spatial Resolution >= 500 PPI/DPI, Contrast Resolution of >= 12 Bits/Pixel, Preferably with Standard Film Sorter at the Output for sorting the Films Bases On Modality Connected Access Time For First Film Should Be 90 Seconds Or Less The Dry Imager should be DICOM Compatible for Receive Sent And Print Facility and it should allow (for multi loading CR System) at least Allow Three Sizes From the Five Sizes To Be Loaded at Any Time Printer Status Should Be Displayed For Any Error Status EtcYes
Dry Imager should be with Preferably with Standard Film Sorter at the Output for sorting the Films Bases On Modality Connected Access Time For First Film Should Be <= 90 SecondsYes
Dry Imager should be DICOM Compatible for Receive Sent And Print Facility, Printer status should Be Displayed For Any Error Status EtcYes
Dry Imager should allow (for MLCRS) >= 3 sizes from the 5 Sizes to be loaded at any timeYes
Number of online sizes (at least) out of 8 x10, 10x 12, 14x 14, 14×17 sizes, available in the Dry Imager3 online sizes for offered multi loading computed radiography system
For the largest size, Dry Imager (For Film Printing) have a normal through put (Films Per Hour) of at least of> = 75 online sizes for offered multi loading computed radiography system

CONNECTIVITY & SCALABILITY

Interconnectivity Between Various CR Modules Should Be Ethernet BasedYes
Scalability : The CR System Should Have Scope Of Adding Advanced Quality Software For Image Processor, Workstations Connectivity To Any DICOM Archive Or Image Management Systems (PACS)Yes

ADVANCED QC VIEWER

Advanced QC Viewer shall be with 19 Inch High Resolution Medical Grade Monitor for reviewing of the ImagesYes
Advanced QC Viewer should be a separate Module For being able to be kept away From The Digitizer/ CR Reader In the room of choiceYes
Advanced QC Viewer should have features; (i) Window leveling, Annotation, Printing, Rotating, Flipping, Panning, Zooming All Image Post ProcessingYes
Advanced QC Viewer should have features; (ii) Should Have Hospital Information System (HIS) Connectivity (iii) There Should Be Provision For Adding Marker On The FilmYes
Advanced QC Viewer should have features; (iv) It should be possible To Write Images On A CD/DVD:Yes

POWER BACK UP

The Entire Equipment Should Be Supplied With UPS of The Required Rating And Sufficient To Provide At Least 30 Minutes Back Up For The Whole SystemYes

CERTIFICATION

Should be US FDA / CE (European) /BIS approved product OEM should have ISO certificate for quality standardYes, USFDA approved,Yes, CE(European) approved
Copy of US FDA / CE (European) /BIS approval to be kept in Seller online locker and also made available to buyer on demand Please specify link to document in Seller LockerYES
Availability Of Type Test Reports(TTRs) of The Product From Central Govt/NABL/ILAC Accredited Lab Showing Compliance To The SpecificationNo
Test Report NoNA
Test Report DateNA
Name Of The LabsNA

Reviews

There are no reviews yet.

Be the first to review “COMPUTED RADIOGRAPHY SYSTEM”